About the Omron H3DK-S1 24-240VAC/DC
The Omron H3DK-S1 24-240VAC/DC is a new 22.5 mm wide multi-function timer for DIN rail mounting, offering four operating modes on this variant. It has one SPDT relay output rated 5 A at 250 VAC (resistive load) and screw terminals. The time range is 0.1 s to 1200 h, and the unit accepts a 24 to 240 V supply for both AC and DC, 50/60 Hz for AC.
Omron H3DK-S1 24-240VAC/DC is a timer available from EP4 Solutions in new, unused condition. It is also referenced by the part numbers H3DKS1ACDC24240OMI, H3DK S1 24 240VAC DC.
This item is available to order. Contact our team for the current lead time. Priced at £32.64 excluding VAT.
Suited to DIN-rail mounted control panels where a timer with a relay output and a wide supply voltage range is required.
EP4 Solutions is an industrial distributor, supplying electrical, controls and automation parts to industry since 1994. Trade accounts, quotations and worldwide delivery are available.
Brand new, unused product.
Specification sources: industrial.omron.eu
Specifications
| Manufacturer | Omron |
|---|---|
| Part number | H3DK-S1 24-240VAC/DC |
| Alternative part numbers | H3DKS1ACDC24240OMI, H3DK S1 24 240VAC DC |
| Product type | Timer |
| Condition | New |
| Availability | Available to order |
| Price (ex VAT) | £32.64 |
| Installation type | DIN rail |
| Size | 22.5 mm |
| Terminal type | Screw |
| Output type | Relay |
| Contact description | SPDT |
| Time range | 0.1 s - 1200 h s/h |
| Supply voltage AC | 24-240 V |
| Supply voltage DC | 24-240 V |
| Power supply voltage | 24 to 240 VAC/DC, 50/60 Hz |
| Power consumption (H3DK-S1, at 240 VAC) | 4.5 VA max. |
| Control output contact rating (resistive, cosφ = 1, 250 VAC) | 5 A at 250 VAC with resistive load (cosφ = 1) |
| Ambient operating temperature | −20 to 55°C (with no icing) |
| Degree of protection | IP30 (Terminal block: IP20) |
| Weight | Approx. 120 g |
| Type | Analog |
| Functions | Multi-functional |
| Operating mode | Flicker ON Start (Power ON Start), Interval (Power ON Start), ON Delay (Power ON Start), One-shot Output (Power ON Start) |
| DC ripple | 20% max. |
| Allowable voltage fluctuation range (24 to 240 VAC/DC) | 85% to 110% of rated voltage |
| Minimum power-OFF time (power reset) | 0.1 s |
| Reset voltage | 10% of rated voltage |
| Power consumption (H3DK-S1, at 24 VDC) | 1.1 W max. |
| Control output contact rating (30 VDC) | 5 A at 30 VDC with resistive load |
| Control output contact rating (125 VDC, resistive) | 0.15 A max. at 125 VDC with resistive load |
| Control output contact rating (125 VDC, L/R 7 ms) | 0.1A at 125 VDC with L/R of 7 ms |
| Minimum applicable load | 10 mA at 5 VDC (P reference value) |
| Rated operating voltage and current AC-15 | Ue: 250 VAC, Ie: 3 A |
| Rated operating voltage and current AC-13 | Ue: 250 VAC, Ie: 5 A |
| Rated operating voltage and current DC-13 | Ue: 30 VDC, Ie: 0.1 A |
| Rated insulation voltage | 250 V |
| Rated impulse withstand voltage (altitude 2,000 m max.) | 4 kV (at 240 VAC) |
| Conditional short-circuit current | 1,000 A |
| Recommended fuse | 0216005 (250 VAC, 5 A) manufactured by Littelfuse |
| Insulation resistance | 100 MΩ min. at 500 VDC |
| Dielectric strength (current-carrying parts to exposed metal parts) | 2,000 VAC 50/60 Hz for 1 min. |
| Dielectric strength (control output terminals to operating circuit) | 2,000 VAC 50/60 Hz for 1 min. |
| Dielectric strength (between contacts not located next to each other) | 1,000 VAC 50/60 Hz for 1 min. |
| Impulse withstand voltage (24 to 240 VAC/VDC) | 5 kV between power terminals, 5 kV between current-carrying metal parts and exposed non-current-carrying metal parts |
| Noise immunity | ±1.5 kV |
| Static immunity | Malfunction: 4 kV, Destruction: 8 kV |
| Accuracy of operating time | ±1% of FS max. (±1% ±10 ms max. at 1.2-s range) |
| Setting error | ±10% of FS ±0.05 s max. |
| Influence of voltage | ±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range) |
| Influence of temperature | ±2% of FS max. (±2% ±10 ms max. at 1.2-s range) |
| Scale numbers | 12 |
| Set time ranges | 0.1 to 1.2 s; 1 to 12 s; 10 to 120 s; 1 to 12 min; 10 to 120 min; 1 to 12 h; 10 to 120 h; 100 to 1,200 h |
| Life expectancy (mechanical) | 10 million operations min. (under no load at 1,800 operations/h) |
| Life expectancy (electrical) | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) |
| Vibration resistance (destruction) | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
| Vibration resistance (malfunction) | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions |
| Shock resistance (destruction) | 1,000 m/s² 3 times each in 6 directions |
| Shock resistance (malfunction) | 100 m/s² 3 times each in 6 directions |
| Storage temperature | −40 to 70°C (with no icing) |
| Ambient operating humidity | 25% to 85% |
| Dimensions (width) | 22.5 mm |
| Dimensions (depth) | 100 mm |
| Dimensions (height) | 89.4 mm |
| Contact materials | Ag-alloy + Gold plating |
| Terminal block | 6 terminals |
| Screw tightening torque (recommended) | 0.49 N·m |
| Screw tightening torque (maximum) | 0.98 N·m |
| Solid wire size (maximum) | 2.5 mm² |
| Applicable wire gauge (stranded wire) | AWG18 to AWG22 |
| Safety standards | cURus: UL 508/CSA C22.2 No. 14; EN 50274; EN 61812-1 (pollution degree 2, overvoltage category III); CCC: GB/T 14048.5; LR: Test Specification No. 1-2002 Category ENV 1.2 |